INTELLIFLO ® O i ti i i P/N 356916 Rev. A 4/27/16 If you have questions about ordering Pentair Aquatic Systems replacement parts, and pool products, please contact: CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service and Technical Support, USA (8 A.M. to 4:30 P.M. — Eastern/Pacific Times) Phone: (800) 831-7133 Fax: (800) 284-4151 Web site

Pentair intelliflo display not working. Things To Know About Pentair intelliflo display not working.

11. Encino, CA. Jun 7, 2018. #1. Has anyone tried to connect Jandy iAqualink with the Pentair Intelliflo VSF (011056) ?? This pump can be set to control either speed (like a VS pump) or flow (like a VF pump) so it is supposed to be the best of both worlds. It can also show you Speed (RPM), Flow (GPM), Pressure (PSI) when it is running. However ...Things to make sure of... 1. When the EasyTouch is controlling your IntelliFlo, the pump's display should say "Display not active". 2. For the pump to run there has to be at least one Active Circuit scheduled in the EasyTouch and it needs to be on. Like the Pool Circuit as an example. 3.When my WhisperFlo failed in 2006, I purchased and installed an IntelliFlo #011012. It's been doing great until a couple days ago when I was doing some work on the house's main electrical panel. I noticed later that the pump's display is completely dead, even when disconnected from the IntelliTouch control system. The pump is not coming …If you have questions about ordering Pentair replacement parts, and pool products, please use the following contact information: CUSTOMER SERVICE / TECHNICAL SUPPORT Customer Service (8 A.M. to 4:30 P.M. — Eastern and Pacific Times) Phone: (800) 831-7133 Fax: (800) 284-4151 Web site Visit www.pentair.com for more information about Pentair ...

(*) Note: Older IntelliFlo/IntelliPro 4x160/VS-3050 pumps do not have a control panel display) and do not display “Ext Ctrl.” The SolarTouch controller can cool the pool/spa by circulating water through the solar panels when the solar collectors are at a lower temperature than the pool/spa water (typically at night).I have the ScreenLogic Config app on my iPhone. I went to the IntelliFlo Setup section and see Pump 1 and Pump 2 listed. Pump 1 is my main pump and Pump 2 is my cleaner pump. Both pumps are set to "none," which makes sense since neither was a IntelliFlo. Now that Pump 1 is an IntelliFlo, I know it's obvious that I should set it to VSF.

February 09, 2020. Communication issues are among the most common problems people run into with their Pentair pool equipment. The following problems can be caused by faulty communication: pressing a button on a remote or indoor controller does nothing. an Intelliflo pump won't run the schedule. screenlogic can't control the system.

Jun 20, 2020 · My Pentair pool pump stopped working, and I wanted to show exactly how I, as a DIY-er, troubleshooted the issue. The symptoms were: Pool pump was humming for... #1 Similar threads found, but want to make sure I didn't miss an easier fix. My pump display went dead and the breaker was tripped. Reset the breaker and it …The main pump screen displays IntelliFlo #2 with the assigned circuit name. INTELLIFLO Select another IntelliFlo pump and repeat step 3 to assign a circuit name. 5. When finished, press the BACK button to return to the Equipment screen. IntelliTouch Pool and Spa Control System User’s Guide... Page 69: Filtering ParametersHigh performance pump (28 pages) Swimming Pool Pump Pentair INTELLIFLO 100 Installation And User Manual. Variable speed programmable pump (compatible with intellitouch, easytouch and intellicomm) (36 pages) Swimming Pool Pump Pentair SWIMMEY Series Installation Manual. (25 pages) Swimming Pool Pump Pentair EQ …Open the control panel of the Pentair pool heater and examine the controller fuse. Replace the blown fuse with a new one and turn on the pool heater to check …

Owner: Cool Runnings Hea... Associate Degree. 1,081 satisfied customers. Can not operate the pool pump. Have power, start stop light. Can not operate the pool pump. Have power, start stop green light is on and the green light is on for 'EXT. Control only". Located it Boerne TX, … read more.

First, check the water level in your skimmer. If it’s less than half way up the skimmer, that could be where the air is going. Also, check the basket lid o-ring to make sure it’s getting a good seal. It’s good to go ahead and put some silicon pool lube on the o-ring and put it back in just to ensure that seal.May 18, 2023 · Yes the RS-485 cable.. A single speed pump is controlled by an Aux relay and does not use the RS-485 com port. A VS pump is controlled by the RS-485 cable and is not wired to any Aux relay. It sometimes takes a minute or two for the "Display not Active" screen to go away when you first go into the Service mode. • Instructions on how to factory reset a Pentair IntelliFlo pump. These instruction may not work for all IntelliFlo Models. If these instructions do not work, refer to the Pentair pump’s manual for complete instructions on how to perform a factory reset. 1. If already connected to the Pump Converter Board, disconnect the black comm wireGetting There MENU SETUP EQUIPMENT INTELLIFLO PENTAIR IFLO VS 3050 IFLO VF 3050 POOL IFLO VS 3050... Page 78: Assign Custom Speeds (Rpm) Intelliflo Vs 3050) Note: An IntelliFlo VS 3050 pump can only be assigned as pump #1, #2, #3, or #4. 2. On the next screen, press the left side button next to ASSIGN CUSTOM SPEEDS. …Charlotte. May 13, 2018. #8. Te pump model is:: [h=1]Pentair SuperFlo VS Energy Efficient Variable Speed Pool Pump | 1.5HP Single Phase 115-230V 50-60HZ | 342001 [/h] This pump is supposed to have a 3yr. warranty, but Pentair apparently will not recognize online pump sales under their warranty. It was installed by a Pool Pro.Power Out Failure. The incoming supply voltage is less than 170 VAC. The drive faults to protect itself from over current. The. drive contains capacitors that keep it powered up long. enough to save the current run parameters. If power is. restored during this process, approximately 20.

So now the pump is running with the correct constant power. The problem I am having is with the RPM settings, and the schedule. Problem 1: I have setup 4 speeds for the Intelliflo directly on the easytouch panel, it will only allow me to program 4. There is an RPM setting for POOL, another for SPA, another for "EITHER HEATER" and one for "CLEANER."I would purchase the newer model that has the rotatable display. There are also flow control models that allow you to set a flow rate set-point. DO NOT GET THE SVRS (safety vacuum release system) MODEL. All IntelliFlo and WhisperFlo Pentair pumps use the same wet end design. So there should be no plumbing work necessary.Keywords: pool, all clear, chlorine, Pump, pool pump, PWP, pool heater, chlorinating, pwp pool, pentair intelliflo display not workingThe Pentair IntelliFlo variable speed pool pump runs a lot quieter than a single speed pump. One reason for its quietness is its totally enclosed fan-cooled design. This also prevents bugs or water from interfering with the fan. An additional reason for its quiet operation is its permanent magnet motor. It runs at a lower temperature, which ...Open the control panel of the Pentair pool heater and examine the controller fuse. Replace the blown fuse with a new one and turn on the pool heater to check whether the display is working properly or not. 3. Water Flow Problem. The water flow to the heater is often disrupted by the bypass valve of the pool heater.

Screen… Answered in 42 minutes by: Verified Have a great rest of your day and, Related Pool and Spa Questions My pool pump stopped working in the middle of …

The light icon should turn green. Then go out and look at the actual light and confirm it is on. If it is on, turn the light off using the light button on the EasyTouch. Then confirm that the ScreenLogic light icon goes off. If this works, it proves that your RS-485 com port is working.Double check the speed settings for your intelliflo on your easytouch. Go to settings > intelliflo > pump #1 > speeds. Check your pool speed. Just had a customer last week with the same issue and his pool speed was set to 400 rpms. At this low of a speed it looked like the pump was off. Also check the pumps communication to the panel.Aug 18, 2018 · My scheduled run tines include regular filtration, suction side cleaner, and the 3 waterfall periods. There are never more than 2 schedules that overlap (e.g., the filtration timer is running and then the waterfall kicks in for 30 minutes during the time period. The cleaner period, with a higher pump rpm speed, comes later). It will either say, "Display not Active" or it will show the manual operation display.. If the panel is blank, then either the pump/drive is bad, or you do not have any power going to the pump.. The IntelliFlo gets constant AC power from a circuit breaker inside your EasyTouch..About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright ...Brad, So, it would work ok for a pool tech doing a normal maintenance, like cleaning the pump basket, skimmer baskets, or filter cleanings, but it would not work well for a pool tech that is trying to troubleshoot an issue with schedules, or how the system is running.Jul 8, 2019 · I have had my Pentair intelliflo VS pump just over 2 years now. I just noticed that the LCD screen is blank. it does not show anything. the pump works fine however. I cannot program anything since i can't see what it is i am programming. i check out to replace the screen i need to... www.troublefreepool.com. Also, this youtube video that seem ... The SolarTouch Solar Control System offers full digital control for the most precise, efficient, swimming pool heating possible. The digital thermostat is set with the touch of a button and will monitor the temperature of the pool water and solar collectors. SolarTouch Control System integrates with IntelliFlo and IntelliPro Variable Speed pumps for unparalleled efficiency. Feb 9, 2020 · February 09, 2020. Communication issues are among the most common problems people run into with their Pentair pool equipment. The following problems can be caused by faulty communication: pressing a button on a remote or indoor controller does nothing. an Intelliflo pump won't run the schedule. screenlogic can't control the system. #1 Hello. I have had my Pentair intelliflo VS pump just over 2 years now. I just noticed that the LCD screen is blank. it does not show anything. the pump works fine however.

Yes the RS-485 cable.. A single speed pump is controlled by an Aux relay and does not use the RS-485 com port. A VS pump is controlled by the RS-485 cable and is not wired to any Aux relay. It sometimes takes a minute or two for the "Display not Active" screen to go away when you first go into the Service mode.

A Pump That Knows Your Pool’s Flow. A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3 VSF Pool Pump leverages built-in sensorless flow control for optimum water flow adjusts to pool conditions, keeping your pool performing at its best. Set up, monitor and operate the pump from anywhere with ...

My variable speed Pentair pump displays 'Not Active'. None of the buttons work. I have solar heating. Thanks. Submitted: ... We have been working with our professionals to try to help you with your question. Sometimes it may take a bit of time to find the right fit. ... Pentair IntelliFlo VF Variable Flow High Performance 3HP Pool Pump - …(*) Note: Older IntelliFlo/IntelliPro 4x160/VS-3050 pumps do not have a control panel display) and do not display “Ext Ctrl.” The SolarTouch controller can cool the pool/spa by circulating water through the solar panels when the solar collectors are at a lower temperature than the pool/spa water (typically at night). #1 I have a 3 year old Pentair Easy Touch control system that is connected to my Pentair 4 speed pump. While trying to get my controller to talk to my remote I erased the EPROM to reset it (it still doesn't communicate, but that is another problem).Jun 5, 2019. #1. Hello All, Came home from work today to my filter pump not running. This is a Pentair IntelliFlo connected via an Easy Touch Control panel. The breaker is working and I have 110-115 ACV at the breaker terminal in the Easy Touch and I also have the same at the motor electrical connections by testing L1 to GND and L2 to GND.A pool that is crystal clear and inviting is key to the perfect backyard oasis. The IntelliFlo3® VSF Pool Pump leverages built-in sensorless flow control for optimum water flow and adjusts to pool conditions, keeping pools performing at their best. Set up, monitor and operate the pump from anywhere with wireless technology control through the ... See full list on homeadvisorblog.com Chlorine. Liquid Chlorine. Apr 3, 2022. #1. Quick Background: My old Aqualink RS4 cannot control the Pentair Intelliflow installed last year via RS-485 (unsupported). It's a simple single pump system so I have been running the on/off schedule via the Aqualink RS All Button (which basically controls the 240 volt power to the pump).From http://www.swimmingpoolsteve.com/pages/superflo-setup.html - Learn about restarting a Pentair Superflo Variable Speed swimming pool pump if is not worki...Find many great new & used options and get the best deals for Genuine Pentair IntelliFlo Keypad LCD Control Panel 176L0675 at the best online prices at eBay! Free shipping for many products! ... item 3 Pentair Intelliflo Keypad Display Assembly Rplcmnt Control Panel Latest Version Pentair Intelliflo Keypad Display Assembly Rplcmnt Control Panel ...Loose wires and a malfunctioning timer can prevent the pump from turning on and off. Tighten the wires with the previously mentioned process, then listen to the clock closely. There should be a clicking sound if the clock is working properly on an external timer. Replace the internal timer if it won’t turn off.The pump will continue to run, but it is not achieving the desired speed because it is running at the maximum flow rate. ... Ensure that the pump display says “ ...

If you’ve recently experienced an issue with your Pentair Intelliflo Display not working, it’s likely due to a power failure or incorrect wiring. To get the display up and running again, check all power connections and ensure …Double check the speed settings for your intelliflo on your easytouch. Go to settings > intelliflo > pump #1 > speeds. Check your pool speed. Just had a customer last week with the same issue and his pool speed was set to 400 rpms. At this low of a speed it looked like the pump was off. Also check the pumps communication to the panel.Jun 30, 2019 · I have the ScreenLogic Config app on my iPhone. I went to the IntelliFlo Setup section and see Pump 1 and Pump 2 listed. Pump 1 is my main pump and Pump 2 is my cleaner pump. Both pumps are set to "none," which makes sense since neither was a IntelliFlo. Now that Pump 1 is an IntelliFlo, I know it's obvious that I should set it to VSF. 5. Goodyear, Arizona. Sep 4, 2021. #5. The green light is just flashing on and off right now, the screen is blank besides the backlight going on and off along with the green light next to the power symbol. Non of the buttons are doing anything right now either. No automation is connected to it.Instagram:https://instagram. pit boss lockhart platinum series problemsfuturistic royale highgolden corral jacksonville fl priceso'reilly's hayward wisconsin Heat pump troubleshooting guide for Pentair pool heaters. Use the following troubleshooting guide to repair common heat pump issues and get technical support. Call Us Nationwide: 1-800-741-9956. ... does not work, recover the charge, remove bulb from SL, unscrew TXV head, shake it, if rattles, replace head (PN KT-45-ZGA), if not, replace TXV ... in doing this synonymesoteric crossword clue 6 letters The reason you have no display is that you do not have the proper power to the pump; you have one leg of 120 volts coming to the pump, that's why you read 120 volts to ground on each leg. ... I have an Pentair Intelliflo Variable Speed Pump 3hp with a P/N 011012 PMP Intelliflo VF serial #03322911104604B date 10/18/2011. ... I have a Screen ... brikelink Chlorine. Liquid Chlorine. Apr 3, 2022. #1. Quick Background: My old Aqualink RS4 cannot control the Pentair Intelliflow installed last year via RS-485 (unsupported). It's a simple single pump system so I have been running the on/off schedule via the Aqualink RS All Button (which basically controls the 240 volt power to the pump).I have a Pentair Variable Speed Intelliflo pump that suddenly stop working. I tried to start the pump through the Pentair Easy Touch control panel as well as with the SpaSide buttons with no luck. Finally I switch the Easy Touch panel to Service mode so that I could start the pump directly from the pump itself. Still no luck.Aug 27, 2022 · The light icon should turn green. Then go out and look at the actual light and confirm it is on. If it is on, turn the light off using the light button on the EasyTouch. Then confirm that the ScreenLogic light icon goes off. If this works, it proves that your RS-485 com port is working.